Black (iron) Friday has started, short, sharp, huge savings!

find out more

We've built an extraordinary reputation. We mean to keep it.

background Layer 1

We add recipes all the time, bookmark your favourites!

Electricity Supply Requirements for Electrickit Advanced Electric Aga cookers

Installation of the electricity supply for your Electrickit Advanced converted Aga cooker must be carried out by a suitably qualified person. We would normally expect to receive a copy of the minor works certificate. 

Cooker switch should be an accessible outlet box in adjacent cupboard, within 30cm of the Aga range cooker. The isolator should not be positioned immediately above or behind the cooker, but must be fitted no more than 1ft / 30cm away from the appliance.

Do you have a module/companion conventional cooker?

You need an additional supply for the conversion. You cannot use the module supply for the Aga unless you want to remove the module, and only when the supply has been tested as sufficient.

Electrickit Advanced Aga Conversion Power Supply Requirements
2 oven 4 oven (warming cupboard) 4 oven (roasting cupboard)
Left solid (2.2kWh) & right solid (1.4kWh) 32amp  32amp 40amp
Left induction (1.6kWh) & right solid (2.2kWh) 32amp 32amp 40amp*
Left induction (3kWh) & right solid (2.2kWh) 40amp* 40amp* 45amp*
Left radiant & right solid (2.2kWh) 40amp* 40amp* 45amp*
Left & right radiant 40amp* 40amp* 45amp**
Left induction (1.6kWh) & right radiant 32amp 40amp* 40amp*
Left induction (3.0kWh) & right radiant 40amp* 40amp* 45amp**

 

* Cooker can be supplied with a 32amp connection provided the left hob is powered by a separate 13amp dedicated switched fused supply.

* Cooker can be supplied with a 40amp connection provided the left hob is powered by a separate 13amp dedicated switched fused supply.

 

Electrickit Advanced Aga Conversion Power Supply Cable Requirements
Diameter
2 oven 6mm ²
4 oven 6mm ²
4 oven (roasting cupboard) 10mm ²


We recommend H07 cable to withstand at least 85c ambient temperatures.

 